Description
Italian boilers.
Indian café
economics.
Commercial espresso machines built on Italian boilers and rotary pumps, calibrated and supported in India by Takumi Brewing Lab. Six configurations, from a single group kiosk machine to a triple boiler flagship.
Built around the two parts that decide your espresso
Boiler and pump. Everything else is housing.
The hardware is Italian
Brewlyn Signature runs Italian boilers and Italian rotary pumps: the same class of components used in machines several times the price. Boilers carry the thermal mass to hold temperature through a rush. Rotary pumps hold 9 bar with almost no pulsation, which is what gives you an even, repeatable extraction instead of a channelled one.
These are not simplified or budget substitutes. They are the parts that define professional espresso, put into a machine priced and serviced for the Indian market.
Consistency is the product
- Shot 200 tastes like shot 1, so your regulars keep coming back
- Stable temperature means a new barista can hit your recipe faster
- Fewer dumped shots is less coffee cost and shorter queues
- Commercial duty components mean fewer service calls in year two
What is inside every Signature
Specification varies by configuration. The engineering approach does not.
Italian boilers
High thermal mass boilers that recover fast and hold temperature through peak service. Heat exchanger, dual, or triple boiler depending on configuration.
Italian rotary pump
Continuous duty rotary pump delivering steady 9 bar with minimal pulsation. Quieter than vibration pumps and rated for all day operation.
PID control per group
Set brew temperature independently on multi boiler models. Hold a light Chikmagalur wash on one group and a darker blend on the other, at the same time.
Manual pressure profiling
Lever driven pressure profiling on dual, triple, and TB HX models. Pre infuse, ramp, and taper to open up sweetness and texture in the cup.
Auto power save
Boilers modulate power and coast on thermal mass through quiet hours, cutting electricity draw by roughly 20 to 30% against continuous heating.
Your café on the machine
Logo engraving and colour choice are included from the dual boiler models upward. The machine on your bar carries your brand, not ours.
Six configurations
Pick by daily volume and menu complexity, not by budget alone. A machine that is one size too small costs more over three years than the difference in price.
1GR Heat Exchanger
One group, one heat exchanger boiler. The compact commercial machine: small footprint, brew and steam together, genuine café output.
- 1 group, single HX boiler
- Italian boiler and rotary pump
- 58 mm commercial group and portafilter
- Simultaneous brew and steam
Best for kiosks, cloud kitchens, office pantries, small format cafés.
1GR Dual Boiler
Separate coffee and steam boilers in a single group body. Full temperature control in the smallest possible commercial footprint.
- 1 group, 2 boilers: coffee and steam
- PID brew temperature control
- Manual lever pressure profiling
- Logo engraving and colour included
Best for specialty cafés, roastery QC labs, tasting bars, brew focused counters.
2GR Heat Exchanger
The two group workhorse. Two baristas, steady steam, robust build, and the lowest cost per cup in the range at mid volume.
- 2 groups, single HX boiler
- Italian boiler and rotary pump
- Two steam wands plus hot water tap
- Direct plumb or reservoir
Best for restaurants, hotel coffee stations, banquets, standard café service.
2GR Dual Boiler
Dedicated coffee boiler and dedicated steam boiler. The point where a café stops managing the machine and starts dialling in coffee.
- 2 groups, 2 boilers: coffee and steam
- PID control, stability within 0.5 C
- Manual lever pressure profiling
- Logo engraving and colour included
Best for specialty coffee shops, busy neighbourhood cafés, single origin programmes.
2GR Triple Boiler
An independent boiler behind each group, plus a dedicated steam boiler. Two different brew temperatures running at once, all service long.
- 2 groups, 3 boilers: 2 coffee, 1 steam
- Independent temperature per group
- Stability within 0.1 C
- Manual lever pressure profiling
Best for multi origin menus, competition prep, flagship specialty counters.
2GR Triple Boiler + HX
Triple boiler control with an added heat exchanger circuit. Hot water and steam recover continuously, so the tenth cappuccino in a row is the same as the first.
- 2 groups, 3 boilers plus HX circuit
- Independent temperature per group
- Uninterrupted steam and hot water at peak
- Full custom finish programme available
Best for high volume flagships, hotels, multi location chains, roastery bars.
Configuration comparison
Every model shares Italian boilers, an Italian rotary pump, a 58 mm commercial group, stainless construction, and auto power save.
| Specification | 1GR HX | 1GR DB | 2GR HX | 2GR DB | 2GR TB | 2GR TB + HX |
|---|---|---|---|---|---|---|
| Groups | 1 | 1 | 2 | 2 | 2 | 2 |
| Boiler architecture | Heat exchanger | Dual boiler | Heat exchanger | Dual boiler | Triple boiler | Triple boiler + HX |
| Independent temp per group | No | Single group | No | Shared boiler | Yes | Yes |
| PID temperature control | Pressurestat | Yes | Pressurestat | Yes | Yes | Yes |
| Manual pressure profiling | Optional | Yes | Optional | Yes | Yes | Yes |
| Steam recovery at peak | Standard | Strong | Standard | Strong | Strong | Continuous |
| Logo engraving and colour | Add on | Included | Add on | Included | Included | Included |
| Indicative daily volume | 50 to 100 cups | 80 to 150 cups | 150 to 250 cups | 250 to 400 cups | 400 to 600 cups | 600 cups and above |
| Typical setting | Kiosk | Specialty micro café | Restaurant, hotel | Specialty café | Flagship counter | High volume flagship |
Scroll the table sideways to see all six configurations
Custom café branding
Logo engraving and a choice of standard colours are included on dual boiler models and above. Beyond that, the machine can be finished to your interior.
Pantone colour
Powder coating in any Pantone shade, matched to your brand palette and signage.
Leather panels
Italian leather side panels in a range of finishes, for a softer bar presence.
Wood accents
Walnut, teak, or bamboo panels and handles, cut to match your counter.
Ambient lighting
Brand colour LED under the drip tray and group heads, on triple boiler models.
What arrives, and what happens after
A machine is a three year relationship. Takumi Brewing Lab installs it, trains your team on it, and services it.
Included with every machine
- Professional installation by a certified technician
- Four hour hands on barista training for your team
- Water filtration consultation and TDS assessment
- Recipe dial in for your beans on your machine
- 12 month parts and labour warranty
In the box
- Brewlyn Signature machine in your chosen configuration
- 58 mm commercial portafilters, one per group
- Single and double shot precision baskets
- 58 mm stainless steel tamper
- Cleaning brush and blind backflush basket
- User manual, maintenance schedule, warranty card
Support that answers
Nationwide service through Takumi certified technicians, with same day response in metro cities and genuine spares held in stock. Preventive maintenance contracts are available from installation.
Running in 40+ cities
Brewlyn machines are on bars in Bengaluru, Mumbai, Delhi, Pune, Chennai, Hyderabad and beyond, from single origin specialty counters to high volume chains, through thousands of extractions a week.
Before you decide
Heat exchanger or dual boiler?
A heat exchanger gives you one boiler doing both jobs: reliable, simpler, and cheaper to run. A dual boiler separates brew from steam so you can set brew temperature exactly. If your menu is milk led and volume driven, HX is enough. If you are selling the origin on the bag, go dual boiler.
Why would I need a triple boiler?
Only if you run two coffees at once. A separate boiler per group lets you hold, for example, 92 C on a light Ethiopian and 94 C on your house blend simultaneously. If you pour one blend all day, a dual boiler does the same work for less.
What does the added HX circuit do on Config 06?
It takes hot water and steam demand off the main boilers. At peak, the tap and the wands stop competing with the groups, so temperature stays flat during the busiest hour of the day.
What power and plumbing do I need?
Single group models generally run on a standard 15 A single phase point. Two group models are usually three phase. We confirm the exact load, drainage, and water line requirement in a site survey before dispatch.
Do I need a water treatment system?
Yes. Water is the single biggest cause of boiler failure in Indian cafés. Filtration is quoted alongside the machine and sized to your incoming TDS and hardness.
Can I see one before buying?
Yes. Bring your beans to the Bengaluru experience centre and pull shots on the configuration you are considering. Demos in other cities can be arranged on request.
Tell us your daily cup count.
We will tell you which one to buy.
No configuration upsell. Send us your volume, menu, and counter space, and you get a straight recommendation with a price.
WhatsApp: +91 98866 06633 · Email: sales@takumibrew.com
Experience centre: JP Nagar 4th Phase, Bengaluru 560078









Reviews
There are no reviews yet.